Digital Status Display
Self Diagnostic Lighting Codes
|
For controller boards version 1.6 and above, |
| Light Sequence | Status | Action |
|
|
Controller Powered Down |
Battery is disconnected or completely drained. [ Instructions for fitting new batteries] |
|
|
NORMAL OPERATION | Batteries fully charged, lift in correct travelling position, all power connected, ready for use. |
|
|
Not charging | If the lift is mid-track, send the lift to either end of the track over one of the charge points. If lift continues with this code: Check the transformer is plugged in and switched on. Check the charge point at the other end of the track; Check the charge point plungers on the carriage are not stuck in. |
|
|
OSG | OverSpeed Governor has been activated. Locate the hand-winding wheel (gray mushroom shaped object approx. 5" in diameter, generally left under the rail on one of the stair treads). Prise out white disk on the carriage next to the red plug (a blunt knife or screwdriver may be required). Place hand-winding wheel into the hole and wind the carriage up the stairs (turn the wheel clockwise - do NOT turn anti-clockwise) maximum of ten turns until the red LED goes out and the green one comes on. Take the hand-winding wheel out of the hole and send the lift to the top of the rail and run it back down again just to check everything is ok. |
|
|
Seat swivel |
Seat not in ride position or micro switch is jammed or needs to be adjusted. Check the seat is locked in the ride position (the back of the seat should be against the wall the lift runs up).
|
|
|
Key switch | Check the lift is switched on at key under the control arm. Try and pull the key out of lock. If it does not pull out the lift is switched on. If it pulls out, place the key back in the lock and turn it clockwise. If the red LED does not go out, it requires a visit by an engineer. |
|
|
Final Limit reached |
|
|
|
Foot-Switch - down side |
These are safety features that stop the lift if it hits any object. There are three on the footrest and two on the carriage itself. The lifts location determines which edges have been activated. Check for obstructions and if none, check the safety edges are moving freely.
|
|
|
Foot-Switch - up side | |
|
|
Safety Cover Switch - up side | |
|
|
Safety Cover Switch - down side | |
|
|
Battery Fault |
|
|
|
Brake Fault | Brake not disengaging. Try the toggle switch. If it will still not go there is a board fault. Requires visit by an engineer. |
|
|
Motor Fault | Either: 25A fuse has blown; the motor has been connected incorrectly; the motor is damaged or the power section on the board has been damaged. Requires visit by an engineer. |